Search results for " prosthesis"

showing 10 items of 441 documents

In vitro comparison of primary stability of two implant designs in D3 bone

2016

Background Primary stability (PS) is a key factor for implant survival rate and depends on implant design or bone quality. The aim of this study was to compare different thread designs implants, evaluating PS with periotest values (PV) and implant stability quotient (ISQ) values through resonance frequency analysis (RFA). Material and Methods A total of 60 implants (Radhex®, Inmet-Garnick S.A., Guadalajara, Spain) were placed in freshly bovine ribs in vitro. Two designs were used: 30 tapered body with single thread design (PHI) and 30 tapered body with double thread design implants (PHIA). Both designs were 4mm wide and 12mm long. Implants were placed according to manufacturer’s guidelines.…

02 engineering and technologyIn Vitro Techniques03 medical and health sciences0302 clinical medicineHounsfield scaleBone qualityMedicineAnimalsGeneral DentistryOrthodonticsDental Implantsbusiness.industryResearchSignificant differenceImplant designDental Implantation Endosseous030206 dentistry021001 nanoscience & nanotechnologyImplant stability quotient:CIENCIAS MÉDICAS [UNESCO]Denture RetentionResonance frequency analysisOtorhinolaryngologyDental Prosthesis DesignUNESCO::CIENCIAS MÉDICASSurgeryCattleImplantOral Surgery0210 nano-technologybusiness
researchProduct

Influence of short implants geometry on primary stability.

2018

Background A correct design is needed in short implants to improve primary stability (PS) in low quality bone. This study aimed to compare PS of double thread and single thread short implants. Material and Methods Thirty implants with single thread design (PHI/SHORT-I) and 30 implants with double thread design (PHIA/SHORT-I) (Radhex®, Inmet-Garnick S.A., Guadalajara, Spain) were placed in 30 randomly selected bovine ribs. PS was assessed in implant stability quotients (ISQ) and periotest values (PV) with Osstell™ and Periotest® devices, respectively. Computed tomographies of the ribs were taken and bone quality was evaluated in Hounsfield Units (HU) using Ez3D Plus software (Vatech Co., Kor…

0206 medical engineeringDentistry02 engineering and technologyBone and BonesDental Prosthesis Retention03 medical and health sciences0302 clinical medicineHounsfield scaleBone qualityMedicineAnimalsGeneral Dentistrybusiness.industryResearchDental Implantation Endosseousfood and beverages030206 dentistry:CIENCIAS MÉDICAS [UNESCO]020601 biomedical engineeringShort implantsOtorhinolaryngologyDental Prosthesis DesignUNESCO::CIENCIAS MÉDICASSurgeryCattleImplantOral Surgerybusiness
researchProduct

A Brief Review of Manufacturing Medical Implants by Single Point Incremental Forming

2018

Abstract SPIF is a relatively new process that can replace conventional deformation processes. Due to the use of generic tools only, the process is suited to achieving unique production or prototypes. The paper presents a brief literature review on current research of single point incremental forming with applications in obtaining medical implants regarding materials and metodology used.

0209 industrial biotechnologyEngineering020901 industrial engineering & automationbusiness.industryMechanical engineeringCranial prosthesis02 engineering and technologyGeneral MedicineSingle point021001 nanoscience & nanotechnology0210 nano-technologybusinessAutomationACTA Universitatis Cibiniensis
researchProduct

Overview of the Development of Hydraulic Above Knee Prosthesis

2017

This paper presents research and development of hydraulically powered above-knee prosthesis (HAKP) and novel prosthetic foot, in order to enable transfemoral (TF) amputees perform stair ascent and other daily activities in as much as possible natural manner. Functions that need exertion of large forces and moments during locomotion such as walking up stairs and slopes cannot be naturally accomplished by commercially available microprocessor-controlled above-knee (AK) prostheses. Also, such prosthetic devices are expensive and unaffordable for major part of amputee population, so mostly used commercial prostheses are energetically passive devices. Deficiency of passive prosthetic devices is …

0209 industrial biotechnologyeducation.field_of_studymedicine.medical_specialtyComputer sciencemedicine.medical_treatmentMotion recognitionPopulation02 engineering and technologyKinematicsAbove knee prosthesisProsthesis03 medical and health sciences020901 industrial engineering & automation0302 clinical medicinePhysical medicine and rehabilitationGait (human)Stairs030220 oncology & carcinogenesismedicineeducationStair ascent
researchProduct

Influence of Biologically Oriented Preparation Technique on Peri-Implant Tissues; Prospective Randomized Clinical Trial with Three-Year Follow-Up. Pa…

2019

Purpose: The objective of this prospective randomized clinical trial (RCT) was to analyze and compare the clinical behavior of three types of prosthesis supported by single implants in the posterior region after three years functional loading. Materials and Methods: Seventy-five implants were divided into three groups according to the type of prosthetic restoration: screw-retained crown (Group GS); cemented crown without finishing line (biologically oriented preparation technique) (Group GBOPT); and conventional cemented crown with finishing line (Group GCC). The clinical behavior of each restoration type was analyzed after 3 years functional loading by analyzing radiographic peri-implant b…

03 medical and health sciencesimplant-supported prosthesis0302 clinical medicinebone loss0502 economics and business05 social sciences050211 marketinghard tissue030206 dentistryGeneral MedicineArticlescrewedcemented BOPTJournal of Clinical Medicine
researchProduct

In Vivo Functional Evaluation of Tissue-Engineered Vascular Grafts Fabricated Using Human Adipose-Derived Stem Cells from High Cardiovascular Risk Po…

2016

Many preclinical evaluations of autologous small-diameter tissue-engineered vascular grafts (TEVGs) utilize cells from healthy humans or animals. However, these models hold minimal relevance for clinical translation, as the main targeted demographic is patients at high cardiovascular risk such as individuals with diabetes mellitus or the elderly. Stem cells such as adipose-derived mesenchymal stem cells (AD-MSCs) represent a clinically ideal cell type for TEVGs, as these can be easily and plentifully harvested and offer regenerative potential. To understand whether AD-MSCs sourced from diabetic and elderly donors are as effective as those from young nondiabetics (i.e., healthy) in the conte…

0301 basic medicineAdultPathologymedicine.medical_specialtyCell typeBiomedical EngineeringAdipose tissueContext (language use)Bioengineering030204 cardiovascular system & hematologyBiochemistryBiomaterials03 medical and health sciences0302 clinical medicineTissue engineeringBlood vessel prosthesisRisk FactorsDiabetes mellitusmedicineAnimalsHumansAgedBioprosthesisTissue Engineeringbusiness.industryMesenchymal stem cellMesenchymal Stem CellsOriginal ArticlesMiddle Agedmedicine.diseaseBiomaterialBlood Vessel ProsthesisRats030104 developmental biologyAdipose TissueCardiovascular DiseasesRats Inbred LewFemaleStem cellbusiness
researchProduct

Influence of supracrestal tissue attachment thickness on radiographic bone level around dental implants: A systematic review and meta-analysis.

2019

The present systematic review and meta-analysis was carried out to determine the extent to which supracrestal tissue attachment (STA) thickness affects marginal bone loss (MBL) around dental implants. An electronic search was conducted in PubMed (MEDLINE), EMBASE, and complementary sources covering the period up to June 2018. The studies were meta-analyzed based on implant position with respect to the alveolar bone crest (crestal/supracrestal). The MBL values were categorized according to STA width (thick/thin). Of the 1062 eligible titles, nine articles were included in the review. The implants were positioned crestal or supracrestal with respect to the alveolar ridge. The difference betwe…

0301 basic medicineDental Implantsbusiness.industryRadiographyDental Implantation EndosseousAlveolar Bone LossDentistrySoft tissue030206 dentistry03 medical and health sciences030104 developmental biology0302 clinical medicineDental Prosthesis DesignMeta-analysisStatistical significanceAlveolar ridgeAlveolar ProcessPeriodonticsMedicineHumansImplantBone levelbusinessDental alveolusJournal of periodontal researchREFERENCES
researchProduct

Radiographic evaluation of conical tapered platform‐switched implants in the posterior mandible: 1‐year results of a two‐center prospective study

2015

Abstract Objective Long‐term success of dental implants depends on healthy peri‐implant soft tissues and adequate bone levels. This prospective study aims to assess bone level changes around implants with internal conical connection and platform‐switching abutments in the posterior mandible. Material and methods Adult patients missing at least two teeth in the posterior mandible and with a natural tooth mesial to the implant site received two or three adjacent internal conical connection implants. After a minimum transmucosal healing period of 8 weeks, single crown restorations were cemented over platform‐switching abutments. Changes in marginal bone levels were measured in standardized per…

0301 basic medicineMalemedicine.medical_treatmentRadiographyAlveolar Bone LossDentistryPilot ProjectsMandibleProsthesisOsseointegrationBone remodeling03 medical and health sciences0302 clinical medicineGermanySurveys and QuestionnairesmedicineHumansProspective StudiesDental implantbone remodelingplatform switchDental ImplantsBone preservationdental implantCrownsPortugalbusiness.industrySoft tissuebone levelDental Implant-Abutment Design030206 dentistryOriginal ArticlesMiddle Aged030104 developmental biologyconical connection implantsPatient SatisfactionoutcomeOriginal ArticleFemaleImplantDental Prosthesis Implant-SupportedOral SurgerybusinessClinical Oral Implants Research
researchProduct

Microbial Colonization of the Peri-Implant Sulcus and Implant Connection of Implants Restored With Cemented Versus Screw-Retained Superstructures: A …

2016

The aim of this study is to investigate peri-implant and intraconnection microflora of healthy implants restored with cemented and screwed superstructures.Patients with two to three implants restored with cemented or screwed restorations and 5 years of follow-up were recruited. Samples were taken from peri-implant sulci, adjacent teeth, and the inner portion of connections. Prevalence of positive sites and bacterial loads for 10 microorganisms were obtained with quantitative real-time polymerase chain reaction. Implant connection permeability to the studied microorganisms was estimated using a standardized bacterial contamination index. Statistical analysis was performed using a generalized…

0301 basic medicinePeri-implantitisCross-sectional studyDental implantmedicine.medical_treatmentDentistryReal-Time Polymerase Chain ReactionProsthesisOsseointegration03 medical and health sciences0302 clinical medicinemedicineHumansDental implantDental Implantsimplant-supportedbusiness.industrymicrobiologydental implant abutment design030206 dentistrySulcusdental prosthesesBacterial Load030104 developmental biologymedicine.anatomical_structureDental Implant-Abutment DesignCross-Sectional StudiesPeriodonticsImplantDental implant; dental implant abutment design; dental prostheses implant-supported; microbiology; peri-implantitis; prosthesis.Dental Prosthesis Implant-Supportedprosthesisbusinessperi-implantitisJournal of periodontology
researchProduct

Wet Chemistry and Peptide Immobilization on Polytetrafluoroethylene for Improved Cell-adhesion

2016

Endowing materials surface with cell-adhesive properties is a common strategy in biomaterial research and tissue engineering. This is particularly interesting for already approved polymers that have a long standing use in medicine because these materials are well characterized and legal issues associated with the introduction of newly synthesized polymers may be avoided. Polytetrafluoroethylene (PTFE) is one of the most frequently employed materials for the manufacturing of vascular grafts but the polymer lacks cell adhesion promoting features. Endothelialization, i.e., complete coverage of the grafts inner surface with a confluent layer of endothelial cells is regarded key to optimal perfo…

0301 basic medicinePolymersGeneral Chemical EngineeringThrombogenicityBiocompatible MaterialsBioengineeringGeneral Biochemistry Genetics and Molecular Biology03 medical and health scienceschemistry.chemical_compound0302 clinical medicineTissue engineeringBlood vessel prosthesisCell AdhesionHumansCell adhesionPolytetrafluoroethyleneCells CulturedPolytetrafluoroethyleneGeneral Immunology and MicrobiologyGeneral NeuroscienceBiomaterial030206 dentistryBlood Vessel ProsthesisEndothelial stem cell030104 developmental biologychemistrySurface modificationEndothelium VascularBiomedical engineeringJournal of Visualized Experiments
researchProduct